MODEL
YFIAYFIA
Restrictive pressure compensator assembly
CAPACITY:CAPACITY: 320 L/min. 320 L/min.
Continued fromContinued from
previous pageprevious page
(X)(X)CONTROLCONTROL
XX Not Adjustable
(D)(D)DIFFERENTIAL PRESSUREDIFFERENTIAL PRESSURE
DD 50 psi (3,5 bar)
HH 200 psi (14 bar)
(N)(N)SEAL MATERIALSEAL MATERIAL
NN Buna-N
VV Viton
(C)(C)
1 2 3 4
5 6 7 8
9 10 11 12
OPTION SELECTION EXAMPLE: YFIAOPTION SELECTION EXAMPLE: YFIAXXDDNNCCAA
PRIMARY CARTRIDGEPRIMARY CARTRIDGE
CC C (with LPJC primary cartridge, Normally open, modulating element)
INCLUDED COMPONENTSINCLUDED COMPONENTS
PartPart DescriptionDescription QuantityQuantity
500-001-114* O-Ring 2
500-001-121* O-Ring 4
811-001-002* Locating Pin 1
A330-006-004* SAE Plug 1
CSABXXN Cartridge 1
LPJCXDN Cartridge - Primary 1
TECHNICAL FEATURESTECHNICAL FEATURES
This assembly is normally used in a multi-station load-sense system or with a pressure compensated pump.
The pressure differential across the orifice (directional valve) varies with flow and system pressure. It is at its highest at zero flow
and drops with increasing flow.
Another term for this assembly is a hydrostat.
MANIFOLD FACESMANIFOLD FACES
FACE GRIDFACE GRID
PRIMARY CARTRIDGE CONFIGURATIONPRIMARY CARTRIDGE CONFIGURATION